Online UPS( 1KVA to 50KVA)
We are one of the leading manufacturers of Online UPS in India.
Description:
Modernised High Tech Computerised & microprocessor equipments require highly reliable & high
Quality Power Supply to match their requiremrnt.
ONLINE UPS:A stable power generator utilizes advence MOSfet High frequency PWM Techonlogy providing
quick transist response to protect your micro Computer and other Computerised sensitive
equipments AC main disturbances, Brown out, Black Out, Voltage variations, frequency deviation &
spikes...
Protect your costly sensitive equipments from damage.
INVERTER:It convert AC to DC very precisely with isolation. the configration sed is of type bridges using MOSFET .
The design based on high frequency snce wave PWM(Pulse with Modulation). Modulation is done on
a carrer a wave of 20KHz, which is beyound the human audible range and thus provides a noiseless performance.
CHARGER:It convert AC to DC Power Supply the static Invertor & maintains the battery in a fully, charged condition. it designed based on thyrister CONSTANT VOLTAGE CURRENT configuration.
BATTERY:In the event of commercial AC power failure batteries supply the power to the invertor. After return the AC power the UPS enables the battery to be recharge as well as providing power to he Load.
OPTONIAL FEATURES Online UPS :
- Static by pass Switch
- Serial Rs 232 interface
- Microprocessor based digital metering
- Remote On/Off pannel
- Remote indicator Pannel
Technical specifications of Online UPS :
AC INPUT a) 200v +_20% single phase
b) 415v +_20% three phase |
or any voltagr range as per as requirement |
Frequency
waveform Harmonic distortion |
50Hz +-0.05Hz or 60Hz +-0.06Hz(crystal controlled True sinewave less then 3%
|
| FREQUENCY |
|
Efficiency |
>93% for 360V DC & above |
| a) 50Hz +-10% |
can also work on genertors |
|
>90% for 180V DC |
| DC OUTPUT |
|
|
>86% for 72V DC/96V/120V |
UPS capicity a) 50KVA & above b) 10KVA to 50KVA c)3KVA to 10KVA c) bello 3KVA |
DC Output Voltage 432V 360V 180V 20V/144V |
Power Factor Overload
Crest Factor |
0.8 lagging to unity 110% for 10 minutes 200% for 5 cycles 400% for 1/2 cycles > 4:1 |
Invertor Output Voltage
Adjustable range Voltage Stability |
230V AC single Phase or 415V AC three phase +-10V AC +- 1% for DC input varation & Output load veration |
Transist Recovery Phase development Audible Noise leval Technology |
within 3 cycles 110% for 10 minutes 200% for 5 cycles 400% for 1/2 cycles 12Oo=1 for 3 phase output less then 40 db microprocessor PWM-IGBT based switchin frequency > 20kc/s |